Extensions
Showing all 18 results
-
MDT Analog I/O 2-fold, flush mounted, 0-10V, In-/Output shiftable
0 out of 5The MDT Analog I/O 2-fold, flush mounted, 0-10V, In-/Output shiftable, is a versatile and compact device designed for seamless integration into building automation systems. Key features include its dual-channel capability, allowing for both input and output functions that can be shifted as needed, and its compatibility with 0-10V signals, making it suitable for a wide range of analog devices. The flush-mounted design ensures a discreet installation, maintaining aesthetic appeal. Benefits include enhanced flexibility in controlling and monitoring various building systems, improved energy efficiency through precise control, and ease of installation. Its unique selling points are its adaptability in function, space-saving design, and reliable performance in managing complex automation tasks.
-
MDT Analog I/O 4-fold, 2SU MDRC, 0-10V, In-/Output shiftable
0 out of 5Analog I/O 4-fold, 2SU MDRC, 0-10 V, In-/Output shiftable. Suitable as analog output to control ventilation systems and other systems with 0-10 V input. Also useful as an analog input to engage rotation speed or other 0-10 V values. Each channel can be configured independently (In-/output). In/outputs are galvanically isolated from the bus. In/outputs are galvanically connected together. Voltage for output operation is generated inside the actuator. No external power supply required. Input operation 0-10 V / 2-10 V or 0-20 mA / 4-20 mA (switchable). – Adjustable conversation of measuring unit and DPT. – Min/max function, wire breakage detection. – Threshold and traffic light function. Output functions 0-10 V: – Control by 1 Byte, 2 Byte or 1 Bit objects. – Day/night function to limit control value. – Emergency mode if given value fails. Quick application download (long frame support for ETS5). 3 year warranty.
-
MDT Binary Input 16-fold, 8SU MDRC, Contact Inputs
0 out of 5Binary Input 16-fold, 8SU MDRC, Contact Inputs. Binary Input to connect potential free contacts. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts. New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs. (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. Internally generated query voltage of 12 V. 3 year warranty.
-
MDT Binary Input 16-fold, 8SU MDRC, Inputs 230 V AC
0 out of 5Binary Input 16-fold, 8SU MDRC, Inputs 230 V AC. Binary Input detection of 230 V AC signals. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts. New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs. (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. 3 year warranty.
-
MDT Binary Input 16-fold, 8SU MDRC, Inputs 24 V AC/DC
0 out of 5Binary Input 16-fold, 8SU MDRC, Inputs 24 V AC/DC. Binary Input detection of 12-24 V AC/DC signals. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts. New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs. (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. 3 year warranty.
-
MDT Binary Input 32-fold, 12SU MDRC, Contact Inputs
0 out of 5Binary Input 32-fold, 12SU MDRC, Contact Inputs. Binary Input to connect potential free contacts. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts. New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs. (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. 3 year warranty.
-
MDT Binary Input 4-fold, 2SU MDRC, Contact Inputs
0 out of 5Binary Input 4-fold, 2SU MDRC, Contact Inputs. Binary Input to connect potential free contacts. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts. New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. Internally generated query voltage of 12 V. 3 year warranty.
-
MDT Binary Input 4-fold, 2SU MDRC, Inputs 230 V AC
0 out of 5Binary Input 4-fold, 2SU MDRC, Inputs 230 V AC. Binary Input detection of 230 V AC signals. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts. New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. Internally generated query voltage of 12 V. 3 year warranty.
-
MDT Binary Input 4-fold, 2SU MDRC, Inputs 24 V AC/DC
0 out of 5Binary Input 4-fold, 2SU MDRC, Inputs 24 V AC/DC. Binary Input detection of 12-24 V AC/DC signals. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts. New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. Internally generated query voltage of 12 V. 3 year warranty.
-
MDT Binary Input 8-fold, 4SU MDRC, Contact Inputs
0 out of 5Binary Input 8-fold, 4SU MDRC, Contact Inputs. Binary Input to connect potential free contacts. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts.
New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. Internally generated query voltage of 12 V. 3 year warranty. -
MDT Binary Input 8-fold, 4SU MDRC, Inputs 230 V AC
0 out of 5Binary Input 8-fold, 4SU MDRC, Inputs 230 V AC. Binary Input detection of 230 V AC signals. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts. New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs. (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. 3 year warranty.
-
MDT Binary Input 8-fold, 4SU MDRC, Inputs 24 V AC/DC
0 out of 5Binary Input 8-fold, 4SU MDRC, Inputs 24 V AC/DC. Binary Input detection of 12-24 V AC/DC signals. LED indicator for each channel, max. input cable length 100 m. To connect push buttons or window/auxiliary contacts. New multi touch function, sends up to 4 values/DPTs on the same or different objects. Innovative group control with long/extra long button press. 4 integrated logical modules, e.g. interpretation of the inputs (e.g. window closed or sending second object). NO or NC contact operation, sending contact status. Operation of blinds and shutters, 1 and 2 button operation. Forced setting function for each output. Scenes, block communication object for each channel. Operation with short/long button push and 2 objects. Counting of pulses, suitable for 30 ms S0 pulses. Cyclical sending, sending after reset. 3 year warranty.
-
MDT IP Interface with IP Secure and Data Secure, 2SU MDRC, with email and time server functions
0 out of 5IP Interface with IP Secure and Data Secure, 2SU MDRC, with email and time server functions. To enable bidirectional communication between PC and the KNX bus via TCP/IP. 4 simultaneous connections possible. Programming the KNX bus via TCP/IP. Power supply by KNX bus, no external bus power supply required. Encrypted transmission at sending emails. Time server functions to send time and date on the KNX bus. Supports extended group addresses. KNX IP Secure and KNX Data Secure (from ETS 5.7). Secure access to the KNX bus through IP Secure with security key. Firmware can be updated. Quick application download (long frame support for ETS5). 3 year warranty.
-
MDT IP Router with IP Secure and Data Secure, 2SU MDRC, with email and time server functions
0 out of 5IP Router with IP Secure and Data Secure, 2SU MDRC, with email and time server functions. Functions as KNX IP Interface, but with KNX line coupler functionality. To enable bidirectional communication between PC and the KNX bus via TCP/IP. 4 simultaneous connections possible. Programming the KNX bus via TCP/IP. Power supply by KNX bus, no external bus power supply required. Encrypted transmission at sending emails. Time server functions to send time and date on the KNX bus. Supports extended group addresses. KNX IP Secure and KNX Data Secure (from ETS 5.7). Secure access to the KNX bus through IP Secure with security key. Firmware can be updated. Quick application download (long frame support for ETS5). 3 year warranty.
-
MDT KNX Modbus Gateway RTU485, 2TE, REG
0 out of 5KNX Modbus Gateway RTU485, 2TE, REG. Designed for bidirectional Data exchange between Modbus RTU- and KNX-products. Master- / Slave-Mode for all channels separately selectable. Comprehensive binary- and arithmetical mathematical functions configurable for each channel. Easy scaling settings. Value range conversion adjustable for each channel. Multi Read / Write Functionality on the Modbus-side. Slave ID for each channel separately configurable. 20 Value comparison blocks each with 4 comparable values and operations. Universal applicable, supports multiple Modbus- and KNX-Data types. No additional Modbus Power supply required. Power is provided over the KNX connection. Modbus / KNX galvanically separated. Developed and produced in Engelskirchen. 3 Year warranty.
-
MDT Line Coupler with Data Secure, 2SU MDRC
0 out of 5Line Coupler with Data Secure, 2SU MDRC. MDRC device. Line Coupler to connect two KNX lines to each other. Electrical isolation between the lines. Separate bus power supply for each line required. Filter functions to reduce bus load. Supports extended group addresses. Supports KNX Data Secure (from ETS 5.7). Quick application download (long frame support for ETS5). 3 year warranty.
-
MDT Logic Modul, 2SU MDRC
0 out of 5Logic Modul, 2SU MDRC. MDRC device, with 4 free to use LED indicators. 24 independent function blocks assignable: Universal logic with up to 5 conditions. Logic gates with (AND,OR/XOR), each with 8 inputs. Cyclical sending or quering of values. Value storage if the bus voltage fails. Monitoring of telegrams, Filter functions. Converting of data point types, Time functions. Multiplexer/Partition control. Min-/Max/Average value, Universal calculator. Converting to PWM, Telegram multiplier/sequencer. Quick application download (long frame support for ETS5). 3 year warranty.
-
MDT USB Interface, 2SU MDRC
0 out of 5USB Interface, 2SU MDRC. MDRC device. To enable bidirectional communication between PC and KNX bus via USB. Fully compatible to ETS3/4/5. PC sleepmode is supported. Firmware can be updated. Quick application download (long frame support for ETS5). 3 year warranty.
End of content